Search
Close this search box.

ScaleRx®: An Innovative Ion Polarization Scale Inhibitor

ScaleRx: Safe & Effective Scale Inhibitor

ScaleRx® is the answer to your hard water problems. Unlike a labor-intensive water softening system, ScaleRx effectively prevents the formation of hard mineral deposits without chemically altering or removing mineral content from water.

Independent testing conducted by IAPMO R&T demonstrates that ScaleRx prevents 76% of scale deposition on heating elements, protecting your home water heater or industrial equipment.

Side-by-side comparison testing reveals ScaleRx is 4 times more effective than the leading electronic scale reduction device.

Save yourself time, money, and the hassle of dealing with scale buildup. Install ScaleRx today.

Explore the ScaleRx Series of Scale Inhibitors

ScaleRx Scale Inhibitor Features

American Valve’s ScaleRx Ion Polarization Scale Prevention systems are designed to treat water with elevated levels of dissolved calcium carbonate or magnesium carbonate to prevent the formation of calcite crystals, or limescale, on downstream components.

Our innovative 4000 Series ball valves are designed with maintenance engineers and facilities manages in mind – easy to open, easy to close, and featuring a patented PFA*-fused ball that resists buildup and corrosion to extend valve life. All 4000 Series ball valves are certified by UL to meet NSF/ANSI Standards 61 and 372 for drinking water safety.

Material Compatibility

Manufactured from 304 stainless steel, ScaleRx devices are suitable for direct connection to a broad range of common pipe materials, including but not limited to plastics, copper-based alloys, and other stainless steels. 

stainless-steel-valve

Connection Options

connection-options

Flanged

Threaded

Use and Maintenance

scale-prevention-residential-homeowner-tankless-water-heater

ScaleRx doesn’t require any maintenance! In fact, over time you may notice previously existing scale deposits break up and flush through piping outlets.

ScaleRx vs. Traditional Water Softeners

Feature ScaleRx Traditional Water Softening Systems
Installation Effort Low/Easy High/Complex
Scale Prevention Effectiveness 4 times more effective than leading electronic devices Less effective; varies by system
Chemical Alternation of Water None Yes, chemically removes mineral content
Maintenance Requirements None Routine maintenance requirements
Material Compatibility Compatible with a broad range of materials Compatible, but may have limitations
Connection Options Multiple (Threaded, Flanged) Limited options
Technology Used Ion Polarization Scale Prevention Various, often salt-based processes

Your Best Defense Against Scale

85% of America has hard water.


Limescale accumulation blocks heat transfer, causes corrosion, and contributes to premature failure of expensive equipment.  ScaleRx® effectively inhibits the formation of limescale deposits and is suitable for a wide range of equipment handling moderate to severe hard water.

scaled pipe cross section

A cross-section of limescale build-up restricting flow.

CONCENTRATION OF HARDNESS AS CALCIUM CARBONATE

 SOFT/SLIGHTLY HARD WATER

 MODERATELY HARD WATER

HARD WATER

VERY HARD WATER

Limescale build-up on a tankless water heater

Limescale build-up on a tankless water heater without ScaleRx® protection in Phoenix, Arizona

Patented TGP™ Technology

HOW DOES SCALERX® WORK?

ScaleRx® effectively disrupts the formation of limescale as cold water enters a tank or tankless water heater system.

Cold water enters the ScaleRx® system and flows through an array of alloy discs that generate a small galvanic current and turbulent flow.

The patented TGP™ process effectively prevents the formation of calcite crystals.

After passing through ScaleRx®, calcium carbonate crystallizes as aragonite, which is less apt to stick to surfaces and flows freely through piping systems.

Flow restriction is minimal—less than 1 GPM pressure drop in 1 in. pipe at 100 psi.  Consult the ScaleRx® specification guide for pressure drop curves.

No maintenance is required.  In residential applications, life expectancy is over 12 years.

scalerx green

After exiting ScaleRx®, calcium carbonate crystallizes as aragonite (GREEN).

Other Solutions to Limescale

ScaleRx requires no filters, power source, or maintenance.  Forget about bags of salt, expensive maintenance contracts, or replacement filters.  Instead of softening water or adding forever chemicals to the water supply, ScaleRx is effortless and effective.  It doesn’t remove or add anything to the water, and is certified to NSF/ANSI/CAN Standards 61 & 372.

Testing by IAPMO R&T has shown that ScaleRx patented TGP™ technology prevented 76% of limescale deposits in a water heater.  Field installations in residential, commercial, and industrial systems alike confirm the laboratory results and demonstrate immediate ROI.

limescale buildup

WITHOUT ScaleRx

WITH ScaleRx

Proven Performance

Testing by IAPMO R&T has shown that ScaleRx patented TGP™ technology prevented 76% of limescale deposits in a water heater.  Field installations in residential, commercial, and industrial systems alike confirm the laboratory results and demonstrate immediate ROI.

commercial scalerx

Diverse Industry Applications

ScaleRx is a solution that spans across industries, including:

Healthcare Facilities

ScaleRx zero-maintenance scale inhibitors are essential for combatting hard water problems and minimizing limescale buildup in critical water systems like yours. Doctors, nurses, healthcare staff, and patients alike depend on clean, reliable water; that means they depend on you.

healthcare-facilities
Water & Wastewater Treatment Plants

In your plant, limescale interferes with equipment like heaters, filters, and flow meters—ultimately creating more work for you. Our ScaleRx zero-maintenance scale inhibitors enhance the efficiency and reliability of your facility, effectively handling limescale buildup in your equipment. Your time is valuable, and we assure you that our straightforward, solutions-oriented approach will save you time and money.

water-and-wastewater-treatment-plants
Hotels & Resorts

As a hotel facilities manager, you want to ensure that your plumbing and HVAC systems run efficiently without burdensome maintenance tasks. Our ScaleRx zero-maintenance scale inhibitors combat the effects of hard water on plumbing systems and water heaters, minimizing the risks of breakdowns and downtime. If you’re looking to avoid the headaches that come with limescale buildup at your hotel or resort property, ScaleRx is the solution for you.

hotels-and-resorts
Homeowners

As a homeowner, you have a lot on your plate. Keeping up with home-maintenance is no easy task. Hard water makes forming a lather for cleaning more difficult.

It also leaves hard mineral deposits on fixtures, dishes, and clothing, creating a nuisance for homeowners. ScaleRx is designed for homeowners looking for a limescale prevention solution that actually works without the need for power, chemicals, or maintenance.

homeowners

Scale Inhibitor FAQs

Water containing high levels of dissolved calcium or magnesium carbonate leaves mineral deposits commonly known as “limescale” or “scale” on plumbing components. These deposits restrict flow, prevent heat transfer, and cause corrosion.

Limescale formation:

  • Restricts flow
  • Slows transfer of heat
  • Decreases efficiency
  • Damages heating elements
  • Decreases water pressure
  • Shortens appliance life span
  • Requires frequent and costly maintenance
  • Leaves unsightly deposits on clothes and dishes
  • Increases energy bills

Over 85% of America has hard water. Limescale accumulation blocks heat transfer, causes corrosion, and contributes to premature failure of expensive appliances and equipment. ScaleRx effectively inhibits the formation of limescale deposits and is suitable for a wide range of equipment handling moderate to severe hard water.

ScaleRx effectively disrupts the formation of limescale as cold water enters a tank or tankless water heater system. ScaleRx contains alloy discs that create a small galvanic current, which prevents the formation of calcite crystals (limescale). Calcium carbonate instead forms aragonite crystals, allowing the mineral content to flow freely through without accumulating on surfaces. Nothing is filtered, removed, or chemically altered.

  1. Cold water enters the ScaleRx system and flows through an array of discs that generate a small galvanic current and turbulent flow.
  2. The patented TGP™ process effectively prevents the formation of calcite crystals.
  3. After passing through ScaleRx, calcium carbonate crystallizes as aragonite, which is less apt to stick to surfaces and flows freely through plumbing systems.

ScaleRx can be installed on any tank or tankless water heater and connects directly to any ¾” Male NPT Copper, PEX, PVC or CPVC pipe. Testing conducted by IAPMO R&T shows ScaleRx to be 76% effective at preventing limescale deposits on copper heating elements. In side-by-side comparison testing it was 4 times more effective than the leading electronic scale reduction device.

ScaleRx:

  • Prevents up to 76% of limescale buildup in equipment and water systems
  • Extends the life and efficiency of equipment
  • Is certified by IAPMO R&T to drinking water standards NSF/ANSI/CAN 61 & 372
  • Requires no filters, power source, or maintenance
  • Acts as a limescale-caused corrosion inhibitor

Traditional water softeners are labor-intensive and time consuming. They require salt, resin beads, circulating water, backflushing, and cleaning in order to chemically alter water. On the other hand, ScaleRx prevents the formation of limescale crystals without water treatment chemicals, filters, or labor. For facilities managers and homeowners alike, the return on investment with ScaleRx as compared to a traditional water softening system is night and day. ScaleRx is truly a “set it and forget it” solution to prevent mineral scale deposits.

ScaleRX can be installed on the main water line to your home or before the inlet of any residential water heater to prevent limescale accumulation. ScaleRx replaces just under 12” of pipe, so you will want to leave enough space to work around any pipe fittings or obstacles.

ScaleRx contains no filters and is maintenance-free. The body is made of 304 stainless steel, and testing has shown that ScaleRx remains effective after 12 years of constant use. Say goodbye to your scale problem with ScaleRx. 

Certainly! The outside components are made of durable stainless steel and made to survive harsh environments. ScaleRx Whole Home comes with optional SharkBite™ fittings which are not rated for outdoor use.

ScaleRx is compatible with hard copper (types L, K and M), PEX, HDPE, PE-RT, CPVC, or and PVC pipe. Brass or plastic adapters may be connected directly to ScaleRx.

ScaleRx contains patented TGP® turbines that create both turbulence and a small galvanic current. These features combine to prevent the formation of calcite crystals. Scale inhibition with ScaleRx keeps your water heater and other equipment free from scale build up. 

Less than 1 GPM pressure drop at household pressures. ScaleRx doesn’t reduce household water pressure.

Contact American Valve Today

Looking for additional information about ScaleRx or our related products?